In order to navigate on the website www.media5corp.com, we recommend upgrading your browser to the latest version of Internet Explorer

Sentinel

Sentinel is a multi-service business platform bundling Session Border Controller and Media Gateway capabilities into a robust, field-upgradable platform designed for medium-size and large enterprises. Sentinel is ideally targeted for applications ranging from 30 to 600 simultaneous sessions.


Mediatrix Sentinel
1 x PRI port telephony card
4 x FXS port telephony card
4 x FXO port telephony card
DSP card

  • Back-to-Back User Agent
  • SIP Header manipulation
  • SIP Registrar
  • SIP Authentication
  • SIP Failover
  • Registration throttling/caching
  • Call Forking
  • Dynamic call routing based on:
    • Peer Monitoring State
    • Registration cache
  • Call Admission Control based on:
    • Call Volume
    • Bandwidth usage
    • Concurrent calls
  • Near and far-end NAT traversal
  • Audio and Video media relay
  • Codec filtering
  • SIP and Media Encryption
  • UDP/TCP/TLS interworking
  • DTMF interworking
  • SIP (RFC3261)
  • IMS (3GPP TS 24.229)
  • UDP, TCP, and TLS transport
  • IPv4 and IPv6 (dual-stack)
  • Digest Authentication
  • SIP Failover using DNS SRV
  • Multiple Registration/Virtual gateways
  • PRACK (RFC3262)
  • Event Notification (RFC3265)
  • UPDATE (RFC3311)
  • Asserted Identity (RFC3325)
  • Reason Header (RFC3326)
  • ISUP to SIP mapping (RFC3398)
  • REFER (RFC3515)
  • MWI (RFC3842)
  • Replaces header (RFC3891)
  • Referred-by (RFC3892)
  • Session Timers (RFC4028)
  • ANAT (RFC4091)
  • MIKEY (RFC3830)
  • SDES (RFC4568)
  • Dialog Events Package (RFCRFC4235)
  • Conferencing for User Agents (RFC4579)
  • Vocoders:
    • G.711 (A-law and μ-law)
    • G.726
    • G.729a/b
  • T.38 Fax relay
  • Comfort Noise (RFC3389)
  • RTP/RTCP (RFC3550/3551)
  • SRTP/SRTCP (RFC3711)
  • Clear-Channel voice-band-data (RFC4040)
  • RTP events (RFC4733)
  • Configurable jitter buffer
  • Configurable packetization time
  • Routing Criteria:
    • Interface
    • Calling/Called party number
    • Calling/Called URI
    • Time of day, Day of week, and Date
    • Many others
  • Number manipulation using regular expressions
  • Mapping and transformation of Call Properties to/from Sip Headers
  • Hunt groups
  • Compliant with multiple enhanced security protocols offering a rich feature set including:
    • SIP over TLS
    • SRTP with MIKEY key management protocol (RFC 3830 and 4567) and SDES key management protocol (RFC 4568)
    • X.509 Certificate management
    • HTTPS for the exchange of Configuration File and web pages
    • SNMPv3
    • TR-069 management protocols
    • OCSP (Online Certificate Status Protocol) revocation status verification for TLS links
  • Supported Hash:
    • SHA-1 and SHA-2
  • Supported Key Exchange Mechanism:
    • RSA
    • Diffie-Hellman
  • Supported Cyphers:
    • AES (128 and 256 bits)
    • 3DES (168 bits)
    • Blowfish (448 bits)
  • Group 3/Super G3 Fax real-time FoIP over clear channel (G.711), G.726, or T.38
  • T.38 Fax relay (9.6 k, 14.4 k)
  • G.711 Fax and Modem pass-through (RFC4040)
  • Fax tone detection and pass-through on G.711 and G.726
  • MODEM tone detection and pass-through over G.711 and G.726.
  • Supports up to 2 guest OSs
  • Runs most 32/64 bits Windows(tm) and Linux(tm) OSes
  • Boots from and uses USB devices
  • Zero touch Provisioning
  • TR-069, TR-104, and TR-111
  • WEB GUI
  • SSH and TELNET
  • SMNP v1, v2c, and v3
  • Scripts/firmware files uploaded via HTTP, HTTPS, FTP, and TFTP
  • Customizable CDR
  • Event Notifications via Syslog, SIP, Log File, and SMNP Traps
  • PCM capture
  • Packet capture
  • Diagnostic traces
  • Remote activation of service licenses
  • IPv4 – IPv6
  • Multiple IP addresses per link or VLAN
  • Multiple VLANs per link
  • DHCP client
  • PPPoE
  • IEEE 802.1q + DSCP QoS tagging (media, signaling, and mgmt)
  • IEEE 802.1x Wired Authentication
  • LLDP-med
  • Traffic shaping
  • Firewall with stateful inspection, rate-limitation, and automatic black-listing
  • Static routing
  • NAPT
  • DHCP Server
  • Operating temperature: 0°C to 40°C
  • Storage temperature: -20°C to 70°C
  • Humidity: up to 85%, non-condensing
  • Height: 44 mm
  • Width: 485 mm
  • Depth: 330 mm
  • Weight: 7 kg
  • Agency Approvals
    • UL
    • CE Marking
    • FCC
    • NOM – Mexico
  • Safety Standards
    • UL60950-1: 2nd Edition, 2007-03-27
    • CAN/CSA-C22.2 No. 60950-1- 07 2nd Edition, 2007
    • IEC60950-1: 2005, 2nd Edition with all national deviations
    • NOM-019-SCFI-1998
  • Emissions
    • FCC Part 15:2010 Class B
    • EN55022 (2006) Class B
    • EN61000-3-2 (2000) Harmonic current emissions
    • EN61000-3-3 (1995) Voltage fluctuations and flicker (with amendment A1)
  • Immunity
    • EN55024 (2010), with amendments A1 and A2 including the following:
      • EN61000-4-2 (2009), ESD
      • EN61000-4-3 (2006+ A1:2008+ A2:2010), Radiated RF
      • EN61000-4-4 (2004+ A1:2010), Burst Transients
      • EN61000-4-5 (2006), Surge
      • EN61000-4-6 (2009), Conducted RF
      • EN61000-4-11 (2004), Voltage Dips and Interruptions
  • Telecom
    • FCC Part 68: Subpart D, October 2007
    • Industry Canada (CS-03, Issue 9, Part I, Amendments 1,2,3)
    • ETSI TR103050 V.1.2.1 2002
    • TBR21, January 1998
  • 5 x 10/100/1000 BaseT Ethernet ports for RJ-45 connectorss

With a very competitive pricing structure, Sentinel can be ordered as a single chassis with a basic configuration, and later add telephony cards or licenses according to specific needs.

Parts and licenses available for Sentinel are:

  • Base unit: 1 WAN + 4 LAN Gigabit Ethernet, including 8 slots for telephony cards and 3 SBC session licenses
  • 1 x PRI Port telephony card
  • 4 x FXS Port telephony card
  • 4 x FXO Port telephony card
  • DSP card (needed when using FXS or FXO)
  • SBC individual session license
  • SBC 10 session package license
  • SBC 100 session package license
  • ETS 300 102 (ITU-T Q.931)
  • ETSI BRI/NET3
  • ETSI PRI/NET5
  • CLIP, CLIR, and CLIR override
  • COLP, COLR, and COLR override
  • CNIP
  • MSN
  • Call Hold
  • AOC-D/E
  • CFU, CFNR, and CFB
  • Call Diversion
  • Call Rerouting
  • Configurable Tones (dial, ringing, busy, etc.)
  • G.168 echo cancellation
  • Automatic line detection and configuration
  • Group 3/Super G3 Fax real-time FoIP over clear channel (G.711), G.726, or T.38
  • T.38 Fax relay (9.6 k and 14.4 k)
  • G.711 Fax and Modem pass-through (RFC4040)
  • Fax tone detection and pass-through on G.711 and G.726
  • MODEM tone detection and pass-through over G.711 and G.726.
  • Operating temperature: 0°C to 40°C
  • Storage temperature: -20°C to 70°C
  • Humidity: up to 85%, non-condensing
  • Agency Approvals
    • UL
    • CE Marking
    • FCC
    • NOM – Mexico
  • Safety Standards
    • UL60950-1: 2nd Edition, 2007-03-27
    • CAN/CSA-C22.2 No. 60950-1- 07 2nd Edition, 2007
    • IEC60950-1: 2005, 2nd Edition with all national deviations
    • NOM-019-SCFI-1998
  • Emissions
    • FCC Part 15:2010 Class B
    • EN55022 (2006) Class B
    • EN61000-3-2 (2000) Harmonic current emissions
    • EN61000-3-3 (1995) Voltage fluctuations and flicker (with amendment A1)
  • Immunity
    • EN55024 (2010), with amendments A1 and A2 including the following:
      • EN61000-4-2 (2009), ESD
      • EN61000-4-3 (2006+ A1:2008+ A2:2010), Radiated RF
      • EN61000-4-4 (2004+ A1:2010), Burst Transients
      • EN61000-4-5 (2006), Surge
      • EN61000-4-6 (2009), Conducted RF
      • EN61000-4-11 (2004), Voltage Dips and Interruptions
  • Telecom
    • FCC Part 68: Subpart D, October 2007
    • Industry Canada (CS-03, Issue 9, Part I, Amendments 1,2,3)
    • ETSI TR103050 V.1.2.1 2002
    • TBR21, January 1998
  • 1 x PRI E1/T1 port for RJ-45 connectors for ISDN, CAS, and E&M support.
  • Loop Start (various customization)
  • Configurable Tones (dial, ringing, busy, etc.)
  • G.168 echo cancellation
  • DTMF detection and generation
  • Carrier tone detection and generation
  • Silence Detection
  • Voice Activity Detection
  • Caller ID Detection and Generation (FSK and DTMF)
  • Message Waiting Indicator Tone, FSK, and Voltage
  • Automatic Call
  • Emergency Call
  • Hold
  • 2nd Call
  • Call Waiting
  • Call Transfer (Blind/Attended)
  • 3-way Conference (locally mixed)
  • Distinctive Ring
  • Group 3/Super G3 Fax real-time FoIP over clear channel (G.711), G.726, or T.38
  • T.38 Fax relay (9.6 k, 14.4 k)
  • G.711 Fax and Modem pass-through (RFC4040)
  • Fax tone detection and pass-through on G.711 and G.726
  • MODEM tone detection and pass-through over G.711 and G.726.
  • Operating temperature: 0°C to 40°C
  • Storage temperature: -20°C to 70°C
  • Humidity: up to 85%, non-condensing
  • Agency Approvals
    • UL
    • CE Marking
    • FCC
    • NOM – Mexico
  • Safety Standards
    • UL60950-1: 2nd Edition, 2007-03-27
    • CAN/CSA-C22.2 No. 60950-1- 07 2nd Edition, 2007
    • IEC60950-1: 2005, 2nd Edition with all national deviations
    • NOM-019-SCFI-1998
  • Emissions
    • FCC Part 15:2010 Class B
    • EN55022 (2006) Class B
    • EN61000-3-2 (2000) Harmonic current emissions
    • EN61000-3-3 (1995) Voltage fluctuations and flicker (with amendment A1)
  • Immunity
    • EN55024 (2010), with amendments A1 and A2 including the following:
      • EN61000-4-2 (2009), ESD
      • EN61000-4-3 (2006+ A1:2008+ A2:2010), Radiated RF
      • EN61000-4-4 (2004+ A1:2010), Burst Transients
      • EN61000-4-5 (2006), Surge
      • EN61000-4-6 (2009), Conducted RF
      • EN61000-4-11 (2004), Voltage Dips and Interruptions
  • Telecom
    • FCC Part 68: Subpart D, October 2007
    • Industry Canada (CS-03, Issue 9, Part I, Amendments 1,2,3)
    • ETSI TR103050 V.1.2.1 2002
    • TBR21, January 1998
  • 4 x FXS ports for RJ-11 connectors
  • Loop Start (various customization)
  • Configurable Tones (dial, ringing, busy, etc.)
  • G.168 echo cancellation
  • DTMF detection and generation
  • Carrier tone detection and generation
  • Silence Detection
  • Voice Activity Detection
  • Caller ID Detection and Generation (FSK and DTMF)
  • Automatic Call
  • Hold
  • Group 3/Super G3 Fax real-time FoIP over clear channel (G.711), G.726, or T.38
  • T.38 Fax relay (9.6 k and 14.4 k)
  • G.711 Fax and Modem pass-through (RFC4040)
  • Fax tone detection and pass-through on G.711 and G.726
  • MODEM tone detection and pass-through over G.711 and G.726.
  • Operating temperature: 0°C to 40°C
  • Storage temperature: -20°C to 70°C
  • Humidity: up to 85%, non-condensing
  • Agency Approvals
    • UL
    • CE Marking
    • FCC
    • NOM – Mexico
  • Safety Standards
    • UL60950-1: 2nd Edition, 2007-03-27
    • CAN/CSA-C22.2 No. 60950-1- 07 2nd Edition, 2007
    • IEC60950-1: 2005, 2nd Edition with all national deviations
    • NOM-019-SCFI-1998
  • Emissions
    • FCC Part 15:2010 Class B
    • EN55022 (2006) Class B
    • EN61000-3-2 (2000) Harmonic current emissions
    • EN61000-3-3 (1995) Voltage fluctuations and flicker (with amendment A1)
  • Immunity
    • EN55024 (2010), with amendments A1 and A2 including the following:
      • EN61000-4-2 (2009), ESD
      • EN61000-4-3 (2006+ A1:2008+ A2:2010), Radiated RF
      • EN61000-4-4 (2004+ A1:2010), Burst Transients
      • EN61000-4-5 (2006), Surge
      • EN61000-4-6 (2009), Conducted RF
      • EN61000-4-11 (2004), Voltage Dips and Interruptions
  • Telecom
    • FCC Part 68: Subpart D, October 2007
    • Industry Canada (CS-03, Issue 9, Part I, Amendments 1,2,3)
    • ETSI TR103050 V.1.2.1 2002
    • TBR21, January 1998
  • 4 x FXO ports for RJ-11 connectors
  • Operating temperature: 0°C to 40°C
  • Storage temperature: -20°C to 70°C
  • Humidity: up to 85%, non-condensing
  • Agency Approvals
    • UL
    • CE Marking
    • FCC
    • NOM – Mexico
  • Safety Standards
    • UL60950-1: 2nd Edition, 2007-03-27
    • CAN/CSA-C22.2 No. 60950-1- 07 2nd Edition, 2007
    • IEC60950-1: 2005, 2nd Edition with all national deviations
    • NOM-019-SCFI-1998
  • Emissions
    • FCC Part 15:2010 Class B
    • EN55022 (2006) Class B
    • EN61000-3-2 (2000) Harmonic current emissions
    • EN61000-3-3 (1995) Voltage fluctuations and flicker (with amendment A1)
  • Immunity
    • EN55024 (2010), with amendments A1 and A2 including the following:
      • EN61000-4-2 (2009), ESD
      • EN61000-4-3 (2006+ A1:2008+ A2:2010), Radiated RF
      • EN61000-4-4 (2004+ A1:2010), Burst Transients
      • EN61000-4-5 (2006), Surge
      • EN61000-4-6 (2009), Conducted RF
      • EN61000-4-11 (2004), Voltage Dips and Interruptions
  • Telecom
    • FCC Part 68: Subpart D, October 2007
    • Industry Canada (CS-03, Issue 9, Part I, Amendments 1,2,3)
    • ETSI TR103050 V.1.2.1 2002
    • TBR21, January 1998


Advantages

Sentinel allows Service Providers to deploy SIP Trunk and Hosted Services with compelling session border controller (SBC) capabilities. Designed with a flexible architecture, it enables administrators to easily modify SIP signaling and Media to comply with any devices deployed on the customer premises.

  • Interconnect SIP Trunks with any SIP device
  • Ensure Quality of Service
  • Prevent fraud attacks and shield network confidentiality
  • Enable virtualization for third party applications

Sentinel has inherited the VoIP gateway and media adapter capabilities from the class-leading Mediatrix product portfolio. It is scalable up to 240 channels allowing the conversion of PSTN and Legacy PBX communications into SIP-based communications.

Sentinel is also an SBC, addressing a variety of applications including Demarcation Point, Security, SIP Normalization, Survivability, and more. With a Back-to-Back-User-Agent, Sentinel acts as the middle-man for communications between two SIP endpoints. It can apply deep packet inspection, identify specific properties attached to a SIP Request, and execute predefined actions to manage any particular deployment scenario. Sentinel also supports media relay for media anchoring, NAT traversal, and transcoding.

Main Features

 

SBC SessionsMaximum 600 media sessions

  • Survivability
  • Encryption (TLS/SRTP)

Registered UsersMaximum 2000

  • No extra license required

3rd Party ApplicationsUp to 2 virtual machines

Voice ChannelsUp to 240 channels

  • Up to 8 E1/T1 trunks
  • Up to 28 FXS/FXO ports

Network Interfaces1 GE RJ-45 WAN port

4 GE RJ-45 LAN Ports (bridged)

Solutions

See how Sentinel can contribute to your business.

SIP Trunking Deployments

SIP Trunking for Enterprises

For more information

Get in touch with our integration experts or download brochures and technical documents from our Documentation Portal.

Share :